Uro- Tangential Forceps

$287.95

Uro-Tangential forceps, 26 cm, in two figures, with jaws set tangentially to the shaft.

SKU INT-SRG-URO-037 Category Brand: Product ID: 105685

Guaranteed safe checkout

Need Help? Call Us +1 (404) 919-6896
Monday - Friday 8:30 AM - 5:00 PM

Description

Uro-Tangential Forceps

A long forceps whose jaws are set tangentially rather than in line with the shaft. That offset lets the jaws take a structure side on while the shank stays out of the approach, which is the whole reason for the pattern.

The two figures

Both are 26 cm and differ in the angle at which the jaws are set. Figure 1 and figure 2 are supplied individually, and surgeons who use the pattern regularly tend to hold both, since the angle that works is decided by the approach rather than in advance.

Jaws

Atraumatic and longitudinally serrated, closing evenly along their length so a pedicle or a vessel is held rather than pinched. Ring handles with a ratchet, so the hold can be set and left.

Care

The offset at the jaw is a stress point and the place to inspect first. Look for play where the jaws meet the shank, and confirm the jaws still close along their whole length by holding the closed instrument to the light. Brush along the serrations, dry the box joint, and store with the ratchet released.

Specification

  • Length: 26 cm
  • Two jaw angles, figures 1 and 2
  • Atraumatic serrated jaws, ring handles, ratchet
  • Material: surgical stainless steel
  • Reusable, autoclavable, supplied non sterile

Warranty and supply

Three years against manufacturing defects, counted from invoice. Stock is inspected in Atlanta before it ships. See our FAQs for care guidance, or browse the rest of our urology surgical instruments.

The American Urological Association publishes relevant surgical background.

Disclaimer

Catalog photographs are reference images and may show more than one size or variation, so check the option you have selected before ordering. This is a professional use product. Surgical stainless steel contains nickel, and Intrace USA cannot accept liability for allergic or material sensitivity reactions. See the FDA guidance on materials used in medical devices.

  • Standard and Express delivery services are available for all items.
  • Shipping costs are calculated at the checkout page (after delivery option & destination confirmation).
  • Tracking is available for all delivery options.
  • Items are delivered during standard business hours.

Reviews

There are no reviews yet.

Be the first to review “Uro- Tangential Forceps”

Your email address will not be published. Required fields are marked *