Skip to content Skip to footer

Rosen Micro Ear Needle Angled Shaft

$50.00

The Rosen Micro Ear Needle is a high-precision otological instrument specifically engineered for creating clean incisions in the tympanic membrane and manipulating the ossicular chain during stapedectomy and tympanoplasty. It features an ultra-fine, sharp-pointed tip and a slender, tapering shaft that provides surgeons with exceptional tactile feedback and an unobstructed view of the middle ear anatomy. Ergonomically designed with a solid hexagonal handle for superior rotational control, this instrument ensures atraumatic tissue handling and steady leverage for delicate microsurgical procedures in the professional Atlanta medical environment.

Additional information

Weight 5 lbs
Dimensions 5 × 3 × 3 in
Shaft

Angled, Straight

Guaranteed safe checkout

img img img img
 
Need Help? Call Us +1 (612) 423-0756
Monday - Friday 8:30 AM - 5:00 PM
SKU: INT-DGN-ROSMIC-000-001-1 Category: Brand: Product ID: 107366

Description

Rosen Micro Ear Needle

The Rosen Micro Ear Needle by Intrace USA provides a precision-engineered solution for controlled tissue manipulation and reliable access during high-stakes otological procedures such as stapedectomy, myringotomy, and tympanoplasty. We serve the metro Atlanta medical community as a premier local supplier of specialized ENT and microsurgical instruments. Consequently, we ensure that surgical teams in Brookhaven and across the Georgia healthcare network have immediate access to this essential microsurgical needle, meticulously crafted from premium Japanese and French stainless steel to meet the exacting standards of modern otology.

Clinicians utilize these specialized needles to perform safe, atraumatic maneuvers such as evaluating the integrity of the ossicular chain after prosthesis placement or creating precise incisions in the eardrum. The sharp, finely pointed tip is specifically optimized to provide absolute accuracy in narrow anatomical spaces without causing collateral trauma to surrounding structures. Furthermore, they often use this tool with our other ENT microsurgical instruments. The specialized slender shaft is designed to maximize visual clarity under the operating microscope, ensuring the instrument does not obstruct the visual axis during critical phases of the procedure.

Advanced Engineering for Otological Microsurgery

Intrace USA utilizes premium surgical-grade stainless steel to manufacture this device. This material selection ensures the Rosen Micro Ear Needle maintains its exceptional structural integrity and tip precision through years of rigorous clinical use. Our professional team in Brookhaven, GA, hand-inspects every unit.

We guarantee that the tip sharpness, shaft alignment, and handle ergonomics meet absolute professional standards. This meticulous process ensures every instrument meets the strict demands of high-precision otolaryngology and auditory surgery. The satin finish also helps minimize glare under the intense lighting of the surgical microscope. Therefore, the device ensures a consistent operative result throughout every patient encounter.

Key Features of the Rosen Micro Ear Needle

  • Ultra-Fine Sharp Tip: Specifically engineered to facilitate the atraumatic manipulation of the stapes or for making clean incisions in the tympanic membrane with pinpoint accuracy.
  • Slender Tapering Shaft: Designed to provide an unobstructed line of sight and reduced physical interference during microsurgical maneuvers within the ear canal.
  • Optimal 16cm (6.25″) Profile: The slender, balanced reach provides superior accuracy in narrow anatomical recesses, making it ideal for deep-seated microsurgical maneuvers.
  • Ergonomic Hexagonal Handle: Features a solid, non-slip design to provide the practitioner with maximum rotational control and tactile feedback, reducing hand fatigue.
  • Premium Japanese & French Steel: High-grade surgical materials protect against corrosion and maintain mechanical integrity through repeated high-pressure sterilization cycles.

Clinical Utility in Stapedectomy and Tympanoplasty

Surgeons primarily utilize these needles during ear surgery to evaluate the movement of the malleus and incus or to precisely reposition tissue grafts with absolute accuracy. They are especially valuable in reconstructive cases where a high degree of precision is required to manage the delicate ossicular chain without causing inner ear trauma. Because the Rosen Micro Ear Needle provides a controlled mechanical action and superior visibility, it is a preferred choice for otolaryngologists and reconstructive specialists across the Atlanta medical system.

The instrument creates a stable operative environment by refining the access to the underlying anatomy with pinpoint accuracy. Furthermore, the robust construction ensures the tip does not flex under the pressure of manual manipulation. Therefore, this method ensures a safe clinical area. Intrace USA manufactures this equipment to meet the highest safety requirements, aligning with FDA guidelines on medical device materials.

Maintenance and Sterilization Protocols

Clean the instrument with a neutral pH detergent immediately after each use. Pay close attention to the micro-tip and the transition to the handle where biological debris can settle. Consequently, you must clean these parts thoroughly using a specialized soft-bristled brush or ultrasonic cleaner before sterilization.

Ensure the tip is checked regularly for alignment and sharpness to maintain precise manipulation capability. We recommend standard steam autoclaving for the best results. Avoid using abrasive cleaning pads, as these can damage the high-polish or satin finish. Moreover, Intrace USA manufactures this product in accordance with FDA, CE, and ISO 13485 quality standards. For more information on our quality standards, please visit our FAQs.

Disclaimer:

We provide images for reference only. These may include variations in tip size (e.g., No. 7, 0.40mm) or exact finish based on the manufacturing lot. Only trained medical professionals should use these instruments. Because they contain surgical-grade materials, they also contain nickel. Therefore, Intrace USA assumes no liability for allergic reactions.

  • Standard and Express delivery services are available for all items.
  • Shipping costs are calculated at the checkout page (after delivery option & destination confirmation).
  • Tracking is available for all delivery options.
  • Items are delivered during standard business hours.

Reviews

There are no reviews yet.

Be the first to review “Rosen Micro Ear Needle Angled Shaft”

Your email address will not be published. Required fields are marked *

Intrace USA © 2026. All rights reserved. | Sitemap | Service Areas | Top Medical Supply Manufacturer & Distributor

Let's Chat

Now Accepting Pre-Orders for November Delivery

Secure Your Medical Instruments in Advance

Place your order before October 1st and receive an exclusive 5% discount.

This limited-time offer applies to all standard product lines across our catalog.

Ready to secure your order?

Browse our product catalog or contact us directly for custom and bulk pricing.