Description
Citelli Punch
The Citelli Punch by Intrace USA provides a precision-engineered solution for controlled bone excision and tissue debridement in the mastoid and paranasal sinuses. We serve the metro Atlanta area as a premier local supplier of high-end ENT and otology instruments. Consequently, we ensure your surgical team in Brookhaven and the surrounding Georgia medical community has immediate access to this essential upward-biting punching tool.
Surgeons utilize this specialized instrument to perform clean, mechanical resections within the narrow confines of the ear canal or the sphenoid ostium. This ensures the protection of surrounding delicate neurovascular structures while effectively debulking diseased bone or granulation tissue. Furthermore, they often use this tool with our other ENT surgery instruments. The specialized upward-cutting geometry ensures that the practitioner can maintain absolute control during high-precision otologic and rhinologic work.
Advanced Design for High-Precision Debridement
Intrace USA utilizes premium surgical-grade German and Japanese materials to manufacture this device. This material ensures the Citelli Punch maintains its sharp cutting edges and structural alignment through years of rigorous clinical use. Our professional team in Brookhaven, GA, hand-inspects every unit.
We guarantee that the jaw alignment, spring tension, and handle ergonomics meet absolute professional standards. This meticulous process ensures every instrument meets the strict demands of high-precision endoscopic sinus surgery (FESS) and mastoidectomy. The satin finish also helps minimize glare under the intense lighting of the surgical microscope. Therefore, the device ensures a consistent operative result throughout every patient encounter.
Key Features of the Citelli Punch
- Upward-Cutting Jaw Geometry: Designed with a specialized upward-biting tip to facilitate precise tissue removal in tight anatomical spaces. This variety is critical for maintaining mechanical accuracy during atticus debridement or sphenoidotomy.
- Slender Low-Profile Shaft: The elongated shaft provides deep access within the auditory canal or nasal vault without obstructing the surgeon’s view. Consequently, the practitioner gains superior accuracy in deep anatomical recesses.
- Spring-Loaded Handle: Features an ergonomic, textured grip to provide the practitioner with maximum tactile feedback and a non-slip hold. This design reduces hand fatigue during lengthy microsurgical procedures.
- Multiple Bite Sizes: Available in graduated bite dimensions (typically 1mm, 2mm, and 3mm) to accommodate diverse anatomical requirements. This design is critical for ensuring fluid transitions during complex microsurgical steps.
- Premium Surgical Composition: High-grade materials protect against corrosion and maintain mechanical integrity through repeated high-pressure sterilization cycles.
Clinical Utility in Otology and Rhinology
Surgeons primarily utilize the Citelli Punch during mastoid surgery to remove diseased bone and air cells or to contour the ear canal walls. They are also essential in sinus surgery for opening the sphenoid sinus or removing obstructive bony fragments in the ethmoid region. Because the instrument provides a controlled mechanical action and superior visibility, it is a preferred choice for reconstructive ear surgeons and neuro-otologists.
It creates a stable operative environment by refining the access to the underlying anatomy with pinpoint accuracy. Furthermore, the robust construction ensures the jaws do not splay under the pressure of dense cortical bone. Therefore, this method ensures a safe clinical area. Intrace USA manufactures this equipment to meet the highest safety requirements, aligning with FDA guidelines on medical device materials.
Maintenance and Sterilization Protocols
Clean the instrument with a neutral pH detergent immediately after each use. Pay close attention to the pivot hinge and the internal cup of the biting jaw where biological debris and bone dust can settle. Consequently, you must clean these parts thoroughly using a specialized soft-bristled brush or ultrasonic cleaner before sterilization.
Ensure the spring mechanism is checked regularly for smooth operation and maintain sharp cutting edges for precise performance. We recommend standard steam autoclaving for the best results. Avoid using abrasive cleaning pads, as these can damage the high-polish finish. Moreover, Intrace USA manufactures this product in accordance with FDA, CE, and ISO 13485 quality standards.
For more information on our quality standards, please visit our FAQs. To view our full range of specialty tools, please visit our ENT surgery instruments category page.
Disclaimer:
We provide images for reference only. These may include variations in bite size or jaw angle based on the manufacturing lot. Only trained medical professionals should use these instruments. Because they contain surgical-grade materials, they also contain nickel. Therefore, Intrace USA assumes no liability for allergic reactions.



Reviews
There are no reviews yet.